Concentrated Load Full Panel |
Concentrated Line Load: 300mm Wide Strip |
Unifonm
Load:300mm Wied |
|
|
|
STANDARD FIBERGLASS GRATING DYNAMICS PROPERTY
Concentrated load of full panel and uniform load data:
1. 1007¡Á3007¡Á40mm, eye size 40mm¡Á40mm
¡¡
|
Span
(mm) |
Concentrated point load(kgs) width
(90cm) |
Distortion
(mm) |
Uniform load
(kg/sqm) |
Distortion
(mm) |
1000 |
558 |
6 |
860 |
6 |
900 |
690 |
6 |
1172 |
6 |
600 |
2137 |
8 |
5830 |
8 |
|
2.1007¡Á3007¡Á25mm, eye size 40mm¡Á40mm
¡¡ |
Span
(mm) |
Concentrated point load of full panel
under 1% distortion
(kgs) |
Uniform load under 1% distortion
(kgs/sqm) |
250 |
--- |
--- |
500 |
830 |
5200 |
750 |
460 |
1270 |
1000 |
305 |
492 |
|
3. 1007¡Á3007¡Á25mm, eye size 25¡Á100mm
|
Span
(mm) |
Concentrated point load of full panel
under 1% distortion
(kgs) |
Uniform load under 1% distortion
(kgs/sqm) |
250 |
1300 |
--- |
500 |
380 |
3130 |
750 |
207 |
835 |
1000 |
160 |
335 |
|
4. 1220¡Á3660¡Á38mm, eye size 38¡Á38mm
¡¡ |
Span
(mm) |
Concentrated point load of full panel
under 1% distortion
(kgs) |
Uniform load under 1% distortion
(kgs/sqm) |
457 |
--- |
8503 |
610 |
900 |
3592 |
762 |
660 |
1710 |
914 |
570 |
1075 |
1067 |
418 |
685 |
1219 |
318 |
464 |
|
|
5. 1220¡Á3660¡Á50mm, eye size 50¡Á50mm
|
Span
(mm) |
Concentrated point load of full panel
under 1% distortion
(kgs) |
Uniform load under 1% distortion
(kgs/sqm) |
610 |
1558 |
6328 |
762 |
1000 |
3226 |
914 |
704 |
1881 |
1067 |
581 |
1173 |
1219 |
504 |
782 |
|
REMARKS:
1.The above information is just for your reference, and cannot
be used as the guarantee when using;
2.If you need more information please contact our technical department;
3.Slip-resistant covered grating of 4mm will add 15% strength
|
|
Front page
¡¡
|